CJSE

PRODUCT CENTER

Your location:
Homepage
/
SZS Series Oil / Gas Boiler

PRODUCTS

PRODUCTS

Hot Line:400-0530-636

Tel:+86-530-7355311

E-mail:zhangteng@c-jsec.com

             heguowaimao@163.com

Fax:+86-530-7355311

Add:Heze City, Shandong Province, China

SZS系列燃油(气)锅炉
17.SZS系列燃油燃气锅炉 (2)

SZS Series Oil / Gas Boiler

Pressure level: ≤2.5MPa
Specifications: Steam boiler: 10 ~ 50T / h
Hot water boiler: 7 ~ 46MW
Application industry: steam boiler: widely used in various industrial industries, such as textile, chemical, papermaking, machinery, food, agricultural product processing industries, etc.
Hot water boiler: It is widely used in heating, bathing and domestic hot water in hotels, schools, guesthouses, and communities. Hot water boiler: widely used for heating, bathing and living in hotels, schools, communities and other enterprises and institutions
SZS系列燃油(气)锅炉
17.SZS系列燃油燃气锅炉 (2)
Product Description
 Product Brief

  Adopt D-type layout, natural circulation, double drum water tube boiler, drum longitudinal layout, full membrane water wall structure, micro positive pressure combustion.The furnace is covered by membrane wall, and the flue gas enters the convection tube bundle connecting the upper and lower drum from the furnace outlet.After passing through the convection tube bundle, the flue gas enters the tail heating surface - ND steel spiral fin energy saver and condenser, and finally enters the chimney through the flue to discharge to the atmosphere.

Note:

1. All the above values are calculated based on the low calorific value of natural gas of 8460kcal / Nm3 and the low calorific value of light diesel oil of 10250kcal / Kg. The flue gas condensation rate is calculated as 35%.

2. The total power of the boiler equipment is slightly different according to different burners.

3. Due to the continuous improvement of technology, the final data is subject to the drawing.


 Performance
  1.Full membrane wall structure, no air leakage, small heat loss of smoke exhaust, high thermal efficiency;
  2.Compact structure, small installation volume, saving investment;
  3.Steam boiler adopts natural circulation and large section ratio, hot water boiler adopts forced circulation, water circulation is safe and reliable;
  4.Equipped with well-known high-efficiency brand burners, auxiliary machines and accessories to achieve full-automatic operation;
  5.The feed water pump adopts continuous electric regulation, and has high and low water level alarm interlock protection function;
  6.The furnace is equipped with an inspection hole, which provides great convenience for use and maintenance. The furnace top is equipped with an explosion-proof door.

 Technical Parameters of SZS Series Automatic Oil/ Gas Hot Water Boiler

Boiler Model /Item

SZS10

SZS15

SZS20

SZS25

SZS30

SZS35

SZS40

SZS50

SZS65

Rated evaporation

t/h

10

15

20

25

30

35

40

50

65

Rated steam pressure

MPa

1.25/1.6

1.25/1.6

1.25/1.6

1.25/1.6

1.25/1.6

1.25/1.6

1.25/1.6

1.25/1.6

1.25/1.6

Rated steam temperature

194/204

194/204

194/204

194/204

194/204

194/204

194/204

194/204

194/204

Rated feed water temperature

20(104)

20(104)

104

104

104

104

104

104

104

Calculation of heat exchange area

m2

357.7

524

702.5

805.2

905.2

1052

1208

1512

1998

Design thermal efficiency (oil / gas)

98.48/99.35

98.4/99.3

98.34/99.15

98.1/99.48

98.2/99.2

98.6/99.4

98.64/99.5

98.6/99.4

98.4/99.5

Maximum transport weight of boiler

t

30

40

46.3

52

55.7

68

76

 Spare parts14

 Spare parts14

Boiler water capacity

t

10.1

14.7

16.9

18.9

21.6

23.8

27.7

/

/

Combustion mode

Chamber combustion

Combustion regulation mode

Full automatic proportional adjustment

Applicable fuel

Natural gas, light diesel, coke oven gas

Fuel consumption

Natural gas

Nm3/h

805

1195

1600.7

1972

2190

3060

3060

3825

4893

Light diesel

Kg/h

663

986

1319.1

1598

1860

2540

2540

3175

4128

Power supply

380V/50Hz

Total power of equipment

Diesel fuel

KW

42.5

48.5

70.5

119

137

170.5

170.5

203

265

Gas

KW

38.5

46.5

66.5

108

130

159.5

159.5

188

250

Feed water pump

Electric power

KW

15

15

18.5

30

37

45

45

45

75

Water circulating pump

Electric power

KW

1.5

1.5

3

3

3

4.5

4.5

11

15

Fan

Electric power

KW

22

30

45

75

90

110

110

132

160

Maximum transport size

mm

7490×2790
×3516

9120×3375
×3566

10050×3330
×4066

10200×3800
×4150

10000×4030
×4230

11000×4300
×4230

12000×4300
×4530

15500×4400
×4530

11500×1500
×1800

External interface

Water intake

PN MPa

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

DN mm

50

50

65

65

80

80

80

100

100

Main steam outlet

PN MPa

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

DN mm

150

200

200

200

200

250

250

300

300

Second steam outlet

PN MPa

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

DN mm

40

40

50

50

50

50

50

50

50

Regular drain outlet

PN MPa

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

DN mm

40/50

40/50

40/50

40/50

50

50

50

50

50

Continuous drain outlet

PN MPa

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

DN mm

40

40

40

40

40

40

40

40

40

Safety valve interface

PN MPa

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

1.6(2.5)

DN mm

2×80

2×100

2×100

2×125

2×125

2×150

2×150

2×150

2×150

Chimney size

(mm×m)

φ600×10

φ800×10

φ800×10

φ1000×10

φ1000×10

φ1200×10

φ1200×10

φ1300×15

φ1400×15

  Boiler system - deaeration water supply mode (105 ℃ water supply)
 System diagram of boiler room
ss
 Technical parameters of SZS series automatic gas steam boiler

Boiler Model /Item

SZS7.0

SZS10.5

SZS14

SZS17.5

SZS21

SZS29

SZS46

Rated evaporation

MW

7.0

10.5

14

17.5

21

29

46

Rated steam pressure

MPa

1.0

1.25

1.25

1.25

1.6

1.6

1.6

Rated steam temperature

70

Rated feed water temperature

95/115

115/130

115/130

115/130

130

130

130

Calculation of heat exchange area

m3

240/133

200/150

267/200

334/249

300

414

657

Design thermal efficiency (oil / gas)

70o Backwater

96.1

96.3

96.3

94.38

96.4

96.3

96.4

55o Backwater

98.2

98.5

98.5

95.8

98.1

98.3

98.3

45o Backwater

99.6

99.8

99.8

98.1

99.3

99.8

99.4

Maximum transport weight of boiler

t

28

37

43.3

47.2

51.4

71

散件

Boiler water capacity

Chamber combustion

Combustion mode

Fully automatic adjustment

Combustion regulation mode

Natural gas, coke oven gas, light diesel

Fuel consumption

Natural gas

Nm3/h

760

1130

1510

1800

3056

3056

4848

Light diesel

Kg/h

632

938

1225

1530

2530

2530

4013

Power supply

KW

26

34

49

79

121

121

175

Total power of equipment

Diesel fuel

KW

22

30

45

75

110

110

160

Gas

KW

22

30

45

75

110

110

160

Feed water pump

Electric power

PN MPa

1.6

1.6

1.6

1.6

1.6

1.6

1.6

DN mm

200

250

200

200

250

250

350

Water circulating pump

Electric power

PN MPa

1.6

1.6

1.6

1.6

1.6

1.6

1.6

DN mm

200

250

200

200

250

250

350

Fan

Electric power

PN MPa

1.6

1.6

1.6

1.6

1.6

1.6

1.6

DN mm

50

50

50

50

50

50

50

Maximum transport size

PN MPa

1.6

1.6

1.6

1.6

1.6

1.6

1.6

External interface

Water intake

DN mm

2×80

2×100

2×100

2×125

2×150

2×200

2×200

Main
Steam
outlet

(mm×m)

φ600×10

φ800×10

φ800×10

φ1000×10

φ1200×10

φ1200×10

φ1400×15

 

未找到相应参数组,请于后台属性模板中添加
Last
Next
Username used for comment:
客户留言
Description:
验证码
cjse

Shandong Zhongjie Pressure Equipment Co., Ltd. highly focuses on green energy special equipment industry...

MENU

 

> Data
> Policy
> Repair
> Q & A
> Videos

CONTACT

Hot Line:400-0530-636

Tel:+86-530-7355311

E-mail:zhangteng@c-jsec.com       

    info@c-jsec.com

Fax:+86-530-7355311

Add:Heze City, Shandong Province, China

WECHAT

WECHAT

Copyright © Shandong Zhongjie Pressure Equipment Co., Ltd.        鲁ICP备11026805号      Powered by 300.cn